(23/12/2005)
NDC were recently called to a problem with a Hitachi model VWS150HF3EH 150 kW AC Variable Speed Drive(VSD ).The customer is a leading manufacturer of precision measuring equipment and instrumentation for the industrial process industry

A Service Engineer was despatched immediately to site in an attempt to effect a ' Rapid ' repair however diagnosis revealed that the failure was due to blown components which required the 100 kg drive to be removed from site to NDC ' s Manchester laboratory. As part of NDC's 'care package', parts were readily available just in case of such eventualities, these were fitted, the drive refurbished and fully tested before being reinstalled on site.The VSD ' turned round ' within 24 hours before being reinstalled at the customers site resulting in minimal disruption to the customers manufacturing process....a case of a ' measurable ' success.


Back to news archive

© 2012 - 2017 NDC - all rights reserved